To say that the quality of concrete mixing station belongs to our Chunyue company's mixing station, concrete batching plant zhengzhou China, cheap price, quality assurance, low repairing rate, good performance of concrete batching plant zhengzhou China, high efficiency, professional after-sales service team, excellent technical team, the company's large scale, our company's good reputation, good reputation, has been recognized by most foreign customers.

Want to know about Zhengzhou concrete mixing station? Want to know concrete batching plant zhengzhou China? Our Henan Chunyue concrete mixing station, engaged in mixing station industry for decades, has rich experience, we have accumulated a certain number of old customers, as well as some new customers abroad, praise our mixing station equipment, good reputation.

How to avoid leakage in concrete mixing plant?

1. Is it true that the line leaks electricity?

It is possible to measure the insulation resistance of the transmission line with a megaohmmeter, or to connect an ammeter to the main knife gate, and to connect all mixing station equipment without any equipment. If the ammeter pointer is shaking, the leakage of the transmission line will be indicated.

2. Discrimination is that the leakage between the phase line and the zero line is still the leakage between the phase line and the earth, or both.

The way to distinguish is to block the zero-cut line, or if the indicator of ammeter is unchanged, it is the leakage between the phase line and the earth; if the indicator of ammeter is zero, it is the leakage between the phase line and the zero line; if the indicator of ammeter is smaller but not zero, it is the combination of the two.

3. Determine leakage planning.

Remove the shunt fuse or swing the knife gate, if the ammeter indication remains unchanged, the bus leakage will occur; if the ammeter indication is zero, the shunt leakage will occur; if the ammeter indication becomes smaller but not zero, the bus and shunt leakage will occur.

4. Find out the leakage point.

After the above inspection, the switch of the line lamp is switched on in turn. When switching a switch, if the ammeter indicates zero return, the branch line leaks. If the ammeter indication becomes smaller, it indicates that there is leakage in addition to the branch line. Perhaps it is also possible to use a pen-based segmented test. The leakage point can be found by reducing the search plan in turn.